Steelpro
2288AOQSIN
  • 2288AOQSIN
  • Oxypro-30 chemical oxygen self-rescuer
  • Closed-circuit self-contained breathing apparatus of the chemical oxygen type for evacuation.
    • Self-contained: Not permanently connected to any external oxygen supply (limited duration) and therefore not connected to any fixed element (full mobility ).
    • Closed circuit: It is isolated from the outside, it does not filter the contaminated atmosphere from the environment. The exhaled and inhaled air recirculates within the equipment itself. DO NOT CONFUSE WITH FILTERING RESPIRATORY PROTECTION.
    • Chemical oxygen: The cartridge contains chemicals to absorb CO2 and also absorb humidity and generate oxygen through KO2 (Potassium Peroxide).
    • Evacuation: Only valid for escape situations from the contaminated area. Limited oxygen generation. Not valid for continuous work.
    • It is a respiratory protective equipment that the user wears individually and protects him/her against harmful atmospheres or atmospheres with oxygen deficiency (< 20.5%).
    • Therefore, it is a Personal Protective Equipment and when protecting from a fatal or very serious risk it is a Category III.
    Regulation (EU) 2016/425 on PPE

    Applications
    • In the event of oxygen deficiency, smoke or dangerous gases, these devices provide the user with more time to reach the nearest safe area or make a successful escape from the scene.
    • Confined spaces for construction, maintenance, repair or inspection .
    (Reactors, Storage tanks, sedimentation, etc., Underground transformer rooms. Tunnels. Underground works in general. Sewers. Service galleries. Ship holds. Underground manholes. Transport cisterns).
    • Underground mining.

    RULE AND CERTIFICATION
    Regulation (EU) 2016/425 on PPE.
    EN 13794:2002. Complies with Annex A for underground use.
    EU Type Certificate No. EPT 0477.PPE.19/3366 (Module B).
    Certificate No. EPT 0477.PPE.20/4023 (Module D).
    Certified by: EUROFINS. Product Testing Italy S.r.l.
    Via Cuorgne, nº 21 – 10156 – TORINO - ITALY.
    Notified body nº 0477.

    TECHNICAL CHARACTERISTICS
    ITEM AND SPECIFICATION
    • Reference OXIPRO-30
    • Inhalation temperature ?50 ºC
    • Size (mm) 202x119x191
    • Weight (Kg) 2.2
    • Autonomy of use 30 min at 35 l/min
    • Useful life in transport mode 5 years
    • Useful life in storage 10 years
    • Chemical Oxygen Type K (KO2)


    Ref. Alt.: 2288-AOQ
  • Sizes U
  • Cat. III
    EN 13794
    Tipo KS
  • Logistics
  • Minimum units 1
  • Packaging units 6